Part# |
Description |
Make |
Avail. |
Price |
Qty. |
|
9T92A69G4 |
Weschler Instruments 9T92A69G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Single-Phase | 480V Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) | or 240V Input, 0-560V Output | 60.0 A Rated / 66.0 A Max. | 4-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A69G4 3-Phase |
Weschler Instruments 9T92A69G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (Open Delta Connection) | 60.0 A Rated / 66.0 A Max. | 4-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A7 |
Weschler Instruments 9T92A7 Volt-Pac Variable Autotransformer (Uncased) | Manual, Single-Phase | 120V Input | 0-120V Output (Line Voltage Connection) | 0-140V (Overvoltage Connection) | 6.5 A Rated / 8.0 A Max. | 1-50 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A70 |
Weschler Instruments 9T92A70 Volt-Pac Variable Autotransformer (Uncased) | Manual, Single-Phase | 480V Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) | or 240V Input, 0-560V Output | 70.0 A Rated / 70.0 A Max. | 4-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A70 3-Phase |
Weschler Instruments 9T92A70 Volt-Pac Variable Autotransformer (Uncased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (Open Delta Connection) | 70.0 A Rated / 70.0 A Max. | 4-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A70G4 |
Weschler Instruments 9T92A70G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Single-Phase | 480V Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) | or 240V Input, 0-560V Output | 70.0 A Rated / 70.0 A Max. | 4-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A70G4 3-Phase |
Weschler Instruments 9T92A70G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (Open Delta Connection) | 70.0 A Rated / 70.0 A Max. | 4-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A71 |
Weschler Instruments 9T92A71 Volt-Pac Variable Autotransformer (Uncased) | Manual, Single-Phase | 480V Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) | or 240V Input, 0-560V Output | 90.0 A Rated / 99.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A71 3-Phase |
Weschler Instruments 9T92A71 Volt-Pac Variable Autotransformer (Uncased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (Open Delta Connection) | 90.0 A Rated / 99.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A71G4 |
Weschler Instruments 9T92A71G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Single-Phase | 480V Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) | or 240V Input, 0-560V Output | 90.0 A Rated / 99.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A71G4 3-Phase |
Weschler Instruments 9T92A71G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (Open Delta Connection) | 90.0 A Rated / 99.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A72 |
Weschler Instruments 9T92A72 Volt-Pac Variable Autotransformer (Uncased) | Manual, Single-Phase | 480V Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) | or 240V Input, 0-560V Output | 105.0 A Rated / 105.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A72 3-Phase |
Weschler Instruments 9T92A72 Volt-Pac Variable Autotransformer (Uncased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (Open Delta Connection) | 105.0 A Rated / 105.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A72G4 |
Weschler Instruments 9T92A72G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Single-Phase | 480V Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) | or 240V Input, 0-560V Output | 105.0 A Rated / 105.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A72G4 3-Phase |
Weschler Instruments 9T92A72G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (Open Delta Connection) | 105.0 A Rated / 105.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A74 |
Weschler Instruments 9T92A74 Volt-Pac Variable Autotransformer (Uncased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (WYE Connection) | 50.0 A Rated / 55.0 A Max. | 3-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A74G4 |
Weschler Instruments 9T92A74G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (WYE Connection) | 50.0 A Rated / 55.0 A Max. | 3-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A75 |
Weschler Instruments 9T92A75 Volt-Pac Variable Autotransformer (Uncased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (WYE Connection) | 60.0 A Rated / 60.0 A Max. | 3-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A75G4 |
Weschler Instruments 9T92A75G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (WYE Connection) | 60.0 A Rated / 60.0 A Max. | 3-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A76 |
Weschler Instruments 9T92A76 Volt-Pac Variable Autotransformer (Uncased) | Manual, Three-Phase | 480V Line to Line Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) (WYE Connection) or 240V Input, 0-560V Output | 30.0 A Rated / 33.0 A Max. | 3-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A76G4 |
Weschler Instruments 9T92A76G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 480V Line to Line Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) (WYE Connection) or 240V Input, 0-560V Output | 30.0 A Rated / 33.0 A Max. | 3-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A77 |
Weschler Instruments 9T92A77 Volt-Pac Variable Autotransformer (Uncased) | Manual, Three-Phase | 480V Line to Line Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) (WYE Connection) or 240V Input, 0-560V Output | 35.0 A Rated / 35.0 A Max. | 3-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A77G4 |
Weschler Instruments 9T92A77G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 480V Line to Line Input | 0-480V Output (Line Voltage Connection) | 0-560V (Overvoltage Connection) (WYE Connection) or 240V Input, 0-560V Output | 35.0 A Rated / 35.0 A Max. | 3-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A78 |
Weschler Instruments 9T92A78 Volt-Pac Variable Autotransformer (Uncased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (WYE Connection) | 100.0 A Rated / 110.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|
9T92A78G4 |
Weschler Instruments 9T92A78G4 Volt-Pac Variable Autotransformer (Cased) | Manual, Three-Phase | 240V Line to Line Input | 0-240V Output (Line Voltage Connection) | 0-280V (Overvoltage Connection) (WYE Connection) | 100.0 A Rated / 110.0 A Max. | 6-95 No. of Cores & Frame Size |
WESCHLER INSTRUMENTS |
Available |
request quote |
|
request quote
|